Rapid, selective removal of albumin, IgG, and transferrin to reveal the hidden plasma proteome
Harnessing pioneering affinity-purified duck IgY(ΔFc) polyclonal antibodies, the Good Biotech 3 in 1 Depletion Column line delivers a single-step prefractionation that uncovers low-abundance biomarkers, sharpens 2-DE resolution, and boosts LC/MS sensitivity—all while preserving other clinically relevant proteins.
Why Depletion Columns Matter
High‑abundance proteins can mask critical biomarkers in plasma, leading to:
- Dynamic-range suppression: High-abundance proteins mask critical low-abundance species.
- Heterogeneity artifacts: Charge microvariants smear spots on 2-DE gels.
- Spot crowding: Protein clusters at 45–80 kDa and pI 4.5–6 reduce resolution.
Solution: Efficiently remove albumin, IgG, and transferrin to expose the full plasma proteome.
Advantages of Affinity-Purified IgY(ΔFc) Antibody-Based Depletion Columns
Our three formats—Spin Column, Spin-Kit, and Gravity-Flow Column—employ resin beads, each coupled to duck IgY(ΔFc) antibodies specific for human albumin, IgG, and transferrin:
- Resin volumes: 0.32 mL per spin-format column; 4 mL per gravity-flow column
- Workflow flexibility: Sample sizes from 15 µL to 200 µL
- > 98 % depletion efficiency: Single-pass removal of all three targets (SDS-PAGE verified)
- Exceptional specificity: No binding to complement factors, rheumatoid factor, IgM, or Fc receptors
- Enhanced epitope coverage: Broader recognition of conserved mammalian protein regions compared to mammalian IgG
Key Features
- Selective capture: Exclusively targets albumin, IgG, and transferrin
- Simple operation: Spin-down or gravity-driven protocol—no pumps required
-
High durability:
- Spin formats: > 20 cycles
- Gravity-flow format: > 200 cycles
-
Three formats to suit any workflow:
- Spin Column (REF HD-0301-1.5SC)
- Spin-Kit (REF HD-0301-1.5KT)
- Gravity-Flow Column (REF HD-0301-10GFC)
- Broad compatibility: 1D/2D electrophoresis, LC/MS, Western blotting, immunoassays
-
Customizable Affinity-Purified IgY(ΔFc) Ab-based Depletion Columns
Product name
(REF)
|
Good Biotech 3 in 1 Depletion Column (Spin‑Format)
|
Good Biotech 3 in 1 Depletion Column
(Spin‑Kit)
|
Good Biotech 3 in 1 Depletion Column (Gravity‑Flow)
|
Depletion Method
|
Spin-down
|
Spin-down
|
Gravity-flow
|
Column Size
|
1.5 mL
|
1.5 mL
|
10 mL
|
Resin Beds
|
0.32 mL
|
0.32 mL
|
4 mL
|
Sample Volume
|
15 µl
|
15 µl
|
200 µl
|
Depletion Rate:
Albumin
IgG
Transferrin
|
>98%
|
>98%
|
>98%
|
Enriched Protein Yield (per column/run)
|
280-330 µg
|
280-330 µg
|
3.0-3.4 mg
|
Reuse Cycles*
|
> 20
|
> 20
|
> 200
|
Package
|
Spin Column x 2
|
Spin Column x 2
Equilibration Buffer 80mL
Elution Buffer 60mL
|
Depletion Column x 1
|
Custom Solutions
Design your ideal depletion column. Select the format, resin volume, and flow method that match your sample size and throughput.